tGW-735i Tiny Modbus Gateway with 32 Bit ARM CPU, 10/100Mbit/s Ethernet LAN, 3x RS485 Serial COM, PoE, Modbus, Webinterface The tGW-735i is a compact Tiny Modbus Gateway that supports TCP and ASCII as a Remote Terminal Unit (RTU) to enable communication in automated and actively monitored SCADA systems and to allow monitoring or control from a remote embedded PC or server. The Modbus Gateway tGW-735i is equipped with a powerful 32-bit ARM MCU as microcontroller, which has low power consumption with high performance. For maximum fail-safety, the module uses two independently operating watchdogs, one monitoring the CPU and the other the software, to automatically trigger a reset and restore a working state in the event of a malfunction. As its primary task, the RTU converts TCP to ASCII and vice versa so that secure communication can be established with remote hardware such as sensors, circuits and actuators. Communication with the control server is done via 10/100Mbps LAN, which also provides power over Ethernet (PoE). Three serial ports in RS485 with a maximum bandwidth of 115200bps or a master-slave configuration through the Modbus protocol serve as output. The application areas include various tasks in industrial and automated systems such as smart factory and IoT applications or technical monitoring and control through a Modbus gateway in machine and plant engineering.
tGW-735i Tiny Modbus Gateway with 32 Bit ARM CPU, 10/100Mbit/s Ethernet LAN, 3x RS485 Serial COM, PoE, Modbus, Webinterface The tGW-735i is a compact Tiny Modbus Gateway that supports TCP and ASCII as a Remote Terminal Unit (RTU) to enable communication in automated and actively monitored SCADA systems and to allow monitoring or control from a remote embedded PC or server. The Modbus Gateway tGW-735i is equipped with a powerful 32-bit ARM MCU as microcontroller, which has low power consumption with high performance. For maximum fail-safety, the module uses two independently operating watchdogs, one monitoring the CPU and the other the software, to automatically trigger a reset and restore a working state in the event of a malfunction. As its primary task, the RTU converts TCP to ASCII and vice versa so that secure communication can be established with remote hardware such as sensors, circuits and actuators. Communication with the control server is done via 10/100Mbps LAN, which also provides power over Ethernet (PoE). Three serial ports in RS485 with a maximum bandwidth of 115200bps or a master-slave configuration through the Modbus protocol serve as output. The application areas include various tasks in industrial and automated systems such as smart factory and IoT applications or technical monitoring and control through a Modbus gateway in machine and plant engineering.
Ethernet
Total Ethernet
1
10/100 Mbit/s
1
Interfaces
COM Total
3
RS-485
3
Isolation of COM Ports
3 kV (RS-485)
Supported Protocols
Industrial Protocols
Modbus TCP server, Modbus TCP client, Modbus RTU master, Modbus RTU slave, Modbus ASCII master, Modbus ASCII slave
System Power Input
Input Voltage DC
12..48 V
Power over Ethernet (PoE)
IEEE 802.3af, PoE
Operating Conditions
Operating Temperature
-25..75 °C
Construction
Construction Chassis
Plastic Chassis
Mounting Configuration
DIN-Rail mount
Dimensions and weight
Width
52 mm
Depth
27 mm
Height
95 mm
Connectors
Connectors
Screw Terminal
Cables
Included Cables
кабель питания CA-002 в комплекте
Dimensions
Net Weight
0.07 kg
Gross Weight
0.11 kg
Ethernet
Total Ethernet
1
10/100 Mbit/s
1
Interfaces
COM Total
3
RS-485
3
Isolation of COM Ports
3 kV (RS-485)
Supported Protocols
Industrial Protocols
Modbus TCP server, Modbus TCP client, Modbus RTU master, Modbus RTU slave, Modbus ASCII master, Modbus ASCII slave
System Power Input
Input Voltage DC
12..48 V
Power over Ethernet (PoE)
IEEE 802.3af, PoE
Operating Conditions
Operating Temperature
-25..75 °C
Construction
Construction Chassis
Plastic Chassis
Mounting Configuration
DIN-Rail mount
Dimensions and weight
Width
52 mm
Depth
27 mm
Height
95 mm
Connectors
Connectors
Screw Terminal
Cables
Included Cables
кабель питания CA-002 в комплекте
Dimensions
Net Weight
0.07 kg
Gross Weight
0.11 kg
Ethernet
Total Ethernet
1
10/100 Mbit/s
1
Interfaces
COM Total
3
RS-485
3
Isolation of COM Ports
3 kV (RS-485)
Supported Protocols
Industrial Protocols
Modbus TCP server, Modbus TCP client, Modbus RTU master, Modbus RTU slave, Modbus ASCII master, Modbus ASCII slave
System Power Input
Input Voltage DC
12..48 V
Power over Ethernet (PoE)
IEEE 802.3af, PoE
Operating Conditions
Operating Temperature
-25..75 °C
Construction
Construction Chassis
Plastic Chassis
Mounting Configuration
DIN-Rail mount
Dimensions and weight
Width
52 mm
Depth
27 mm
Height
95 mm
Connectors
Connectors
Screw Terminal
Cables
Included Cables
кабель питания CA-002 в комплекте
Dimensions
Net Weight
0.07 kg
Gross Weight
0.11 kg
Ethernet
Total Ethernet
1
10/100 Mbit/s
1
Interfaces
COM Total
3
RS-485
3
Isolation of COM Ports
3 kV (RS-485)
Supported Protocols
Industrial Protocols
Modbus TCP server, Modbus TCP client, Modbus RTU master, Modbus RTU slave, Modbus ASCII master, Modbus ASCII slave
System Power Input
Input Voltage DC
12..48 V
Power over Ethernet (PoE)
IEEE 802.3af, PoE
Operating Conditions
Operating Temperature
-25..75 °C
Construction
Construction Chassis
Plastic Chassis
Mounting Configuration
DIN-Rail mount
Dimensions and weight
Width
52 mm
Depth
27 mm
Height
95 mm
Connectors
Connectors
Screw Terminal
Cables
Included Cables
кабель питания CA-002 в комплекте
Dimensions
Net Weight
0.07 kg
Gross Weight
0.11 kg
tGW-734
ICP DAS tGW-734 Tiny Modbus/TCP to RTU/ASCII gateway with PoE, 2xRS-232, 1xRS-485
tGW-725i
ICP DAS tGW-725i Tiny Modbus/TCP to RTU/ASCII Gateway with PoE and 2 Isolated RS-485 Ports (RoHS)
tGW-712i
ICP DAS tGW-712i Tiny Modbus/TCP to RTU/ASCII gateway with PoE and Isolated 1 RS-232, 12-48VDC-in

Get a Quote

Recommended products