ICP-DAS Network Diagnostic and Measuring Devices

PM-3033
PM-3033
Modbus RTU, 3-phase power meter (1A/5A CT Input type)
Mounting Configuration
DIN-Rail mount
RS-485
1
Modbus RTU
Slave
Wiring
3P4W-3CT, 3P3W-3CT, 3P3W-2CT, 1P2W-1CT, 1P3W-2CT
Input Voltage
10...500V AC
Input Current
1A/5A
Power Parameter Measurement
True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF)
Temperature
-20 ... 70 °C
 
call
To order
Vendor
ICP DAS
PM-3033-MTCP
PM-3033-MTCP
Modbus TCP, 3-phase power meter (1A/5A CT Input type)
Mounting Configuration
DIN-Rail mount
Total Ethernet
1
10/100 Mbit/s
1
Modbus TCP
Slave
Wiring
3P4W-3CT, 3P3W-3CT, 3P3W-2CT, 1P2W-1CT, 1P3W-2CT
Input Voltage
10...500V AC
Input Current
1A/5A
Power Parameter Measurement
True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF)
 
call
To order
Vendor
ICP DAS
PM-3112-100
PM-3112-100
Modbus RTU; 2 loops single-phase Power Meter with 2 CTs (60 A)
Mounting Configuration
DIN-Rail mount
RS-485
1
Modbus RTU
Slave
Wiring
1P2W-2CT
Input Voltage
10…300V AC
Input Current
60А
Power Parameter Measurement
True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF)
Temperature
-10 ... 70 °C
 
call
To order
Vendor
ICP DAS
PM-3112-100-CPS
PM-3112-100-CPS
CANopen, 2 loops single-phase Power Meter with 2 CTs (60 A)
Mounting Configuration
DIN-Rail mount
CAN Port
1
CAN Version
CANopen, Slave
Wiring
1P2W-2CT
Input Voltage
10…300V AC
Input Current
60А
Power Parameter Measurement
True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF)
Temperature
-10 ... 70 °C
 
call
To order
Vendor
ICP DAS
PM-3112-100-MTCP
PM-3112-100-MTCP
Modbus TCP, 2 loops single-phase Power Meter with 2 CTs (60 A)
Mounting Configuration
DIN-Rail mount
Total Ethernet
1
10/100 Mbit/s
1
Modbus TCP
Slave
Wiring
1P2W-2CT
Input Voltage
10…300V AC
Input Current
60А
Power Parameter Measurement
True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF)
 
call
To order
Vendor
ICP DAS
PM-3112-160
PM-3112-160
ModBus RTU, 2 loops single-phase power meter (100 A)
Mounting Configuration
DIN-Rail mount
RS-485
1
Modbus RTU
Slave
Wiring
1P2W-2CT
Input Voltage
10…300V AC
Input Current
100А
Power Parameter Measurement
True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF)
Temperature
-10 ... 70 °C
 
call
To order
Vendor
ICP DAS
PM-3112-160-CPS
PM-3112-160-CPS
CANopen, 2 loops single-phase Power Meter with 2 CTs (100 A)
Mounting Configuration
DIN-Rail mount
CAN Port
1
CAN Version
CANopen, Slave
Wiring
1P2W-2CT
Input Voltage
10…300V AC
Input Current
100А
Power Parameter Measurement
True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF)
Temperature
-10 ... 70 °C
 
call
To order
Vendor
ICP DAS
PM-3112-160-MTCP
PM-3112-160-MTCP
Modbus TCP, 2 loops single-phase Power Meter with 2 CTs (100 A)
Mounting Configuration
DIN-Rail mount
Total Ethernet
1
10/100 Mbit/s
1
Modbus TCP
Slave
Wiring
1P2W-2CT
Input Voltage
10…300V AC
Input Current
100А
Power Parameter Measurement
True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF)
 
call
To order
Vendor
ICP DAS
PM-3112-240
PM-3112-240
Modbus RTU, 2 loops single-phase power meter (200 A)
Mounting Configuration
DIN-Rail mount
RS-485
1
Modbus RTU
Slave
Wiring
1P2W-2CT
Input Voltage
10…300V AC
Input Current
200А
Power Parameter Measurement
True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF)
Temperature
-10 ... 70 °C
 
call
To order
Vendor
ICP DAS
PM-3112-240-CPS
PM-3112-240-CPS
CANopen, 2 loops single-phase Power Meter with 2 CTs (200 A)
Mounting Configuration
DIN-Rail mount
CAN Port
1
CAN Version
CANopen, Slave
Wiring
1P2W-2CT
Input Voltage
10…300V AC
Input Current
200А
Power Parameter Measurement
True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF)
Temperature
-10 ... 70 °C
 
call
To order
Vendor
ICP DAS

«Configure» — This product have more options and can be configured. Please note that some products can not be ordered without mandatory options.

— New

Vendor
Name
Construction
Mounting Configuration
Interfaces
RS-485
Network Adapter
Total Ethernet
10/100 Mbit/s
Industrial Protocols
Modbus TCP
Modbus RTU
CAN Port
CAN Version
AC Power Measurement
Wiring
Show all Hide
Input Voltage
Input Current
Show all Hide
Power Parameter Measurement
Show all Hide
Operating Conditions
Temperature
°C
-20
70
Dimensions and weight
Width
Height
Depth
Clear filter
Products found: {{ info.count }} Show Nothing Found
https://ipc2u.com/catalog/process-automation/monitoring-and-measuring/netzwork-diagnostic/
10:46 12.12.2018