How to configure MOXA Turbo Ring redundancy protocol?

This article describes the configuration of Turbo Ring V2 protocol for a ring topology using a switch web interface.

This article describes the configuration of Turbo Ring V2 protocol for a ring topology using a switch web interface.

How to configure MOXA Turbo Ring redundancy protocol?
  1. Close the switch web interface
    Default values:
    IP: 192.168.127.254 Login: admin Password: no password
  2. Go to Communication Redundancy. In Redundancy Protocol field specify Turbo Ring V2 protocol type
  3. For the ring topology, tick the box Enable Ring 1
  4. In Redundant Ports field specify numbers of ports used in the ring.

    To define which segment will be used as the redundant path, tick the box near Set as Master. The switch will be assigned with a Ring Master role. In case you skip this step, the redundant path will be selected automatically by Turbo Ring.