There are two types of events, on which the relay actuation can be configured: System events and Port events.

There are two types of events, on which the relay actuation can be configured: System events and Port events.

  1. System events can be configured in System Event Settings tab. A relay output can be configured for 5 events:
    PWR 1 On->Off No supply voltage on PWR1 input
    PWR 2 On->Off No supply voltage on PWR2 input
    Turbo Ring Break Turbo Ring is broken
    DI 1/2 On Digital input 1/2 is on
    DI 1/2 Off Digital input 1/2 is off
    Example of configuration of EDS switches of E series
  2. Events connected to the activity of a certain port can be configured in Port Event Settings tab.

There are 3 types of events:

Link On The port is connected to a device
Link Off Port is disconnected (e.g. the cable is pulled out, the device connected to the port is turned off)
Traffic-Overload The port’s traffic surpasses the Traffic-Threshold for that port
Example of configuration of EDS switches of E series
Example of configuration of EDS switches of A series